Toimintaperiaate / asennus
- The TherMax 12 is suitable for pre-positioned installation.
- The self-tapping, glass-fibre-reinforced cone cuts its own way through the plaster into the insulation during installation.
- The anti-cold cone uses a thermal barrier to minimise heat losses.
- In the case of resistant plaster (e.g. thick cement plaster), it is recommended that the TherMax cutting blade included is used for grinding out the plaster.
- The sealing of the annular gap with the sealant adhesive KD or construction sealant Premium DKM seals the façade at plaster level.